Menu
Edit Template

Resol FRP6 Temperature Sensor 5′ – Gray

For installation in immersion sleeves

Silicone wire 1.5m long

Rated from -5 C to 105 C

Resol EM extension module

Quick access to the manual mode by means of the slide switch

For all optional functions of the DeltaSol® MX, DeltaSol® BX Plus, DeltaSol® SLT and the DeltaTherm® HC/HC MAX

Easy connection via VBus®

Selection and configuration of the functions on the controller

Resol TT2 Thermostat controller

  • Direct connection of an electric immersion heater up to
  • 3.6 kW (230 V~) / 1.8 kW (115 V~)
  • Time and temperature control of the electric backup heating
  • Rapid heat-up function with optional remote control activation
  • Intuitive operating concept
  • Energy-efficient switch-mode power supply
  • Thermosiphon systems

Resol DeltaSol® MX System controller

14 relay outputs and 12 inputs for Pt1000, Pt500 or KTY temperature sensorsUp to 5 extension modules via RESOL VBus® (45 sensors and 39 relays in total)

Inputs for analogue and digital Grundfos Direct Sensors™ as well as for FRH and FRHd humidity sensors

Integrated control of up to 4 high-efficiency pumps via PWM outputs

Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card

Cooling over the heating circuit with condensation detection by means of a dew point switch

Dew point calculation by means of the FRH(d) humidity sensor to avoid condensation

Simplified timer, 0-10 V boiler control and DHW preheating

Resol DeltaTherm® HC MAX Heating controller

  • Up to 5 EM extension modules can be connected via the RESOL VBus® (45 sensors and 39 relays in total), up to 7 weather-compensated heating circuits
  • Inputs for analogue and digital Grundfos Direct Sensors™ as well as for FRH and FRHd humidity sensors
  • Screed drying function
  • Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card
  • Cooling over the heating circuit with condensation detection by means of a dew point switch
  • Dew point calculation by means of the FRH(d) humidity sensor to avoid condensation
  • Modulating heating control with 0-10 V boiler control

Resol DeltaTherm® HC mini Heating controller

4 pre-configured basic systems12 pre-programmed schemes for the temperature controls classes II, III, V, VI, VII and VIII

4 relay outputs (incl. 1 potentil-free extra-low voltage relay)

5 inputs for Pt1000 temperature sensors

5 operating modes, boiler protection, room thermostat and night correction

Holiday mode, chimney sweeper function and screed drying function via microbuttons

Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card

Modulating heating control with 0-10 V boiler control

Resol DeltaTherm® FK Solid fuel boiler controller

2 relay outputs, 4 temperature sensor inputs

2 PWM outputs for the speed control of high-efficiency pumps

Control of an electronic mixer for the return mixing function

Heating backup

Heat exchange function

Thermostatic backup heating

Heat pump demand (optional)

Resol DeltaSol® BX Plus System controller

5 relay outputs and 8 inputs for Pt1000, Pt500 or KTY temperature sensors

Up to 2 extension modules via RESOL VBus® (21 sensors and 15 relays in total)

Inputs for digital Grundfos Direct SensorsTM as well as for FRHd humidity sensors

Integrated control of up to 2 high-efficiency pumps via PWM outputs

Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card

Cooling over the heating circuit with condensation detection

Dew point calculation by means of the FRHd humidity sensor to avoid condensation