The RESOL V40 is a measuring instrument with a contactor for measuring the flow of water or water-glycolmixtures and can be connected directly to the controller or calorimeter for heat quantity measurement. After a specific volume has passed, the V40 reed switch sends an impulse to the calorimeter. The heat quantity used is calculated by these impulses, the temperature difference and pre-defined parameters (glycol type, concentration, heat capacity etc.). Fitting included.
The V40 is available for different thread diameters and nominal flow rates. These types differ in construction, but have the same function and are delivered with connection thread.
Type | V40-15 | V40-25 | V40-35 | V40-60 | V40-150 | ||
---|---|---|---|---|---|---|---|
Product version | 1 | 1 | 2 | 2 | 2 | ||
Impulse rate | l/Imp | 1 | 25 | 25 | 25 | 25 | |
Nominal width | DN | 20 | 20 | 25 | 25 | 50 | |
Connecting thread at the counter | G…B | Zoll | 1 | 1 | 1 ¼ | 1 ¼ | 2 3/8 |
Connecting thread at the screw joint | R… | Zoll | ¾ | ¾ | 1 | 1 | 2 |
Max. operating pressure | Pmax | bar | 16 | 16 | 16 | 16 | 16 |
Max. operating temperature | Tmax | °C | 120 | 120 | 130 | 130 | 130 |
Nominal flow rate | Qn | m3/h | 1,5 | 2,5 | 3,5 | 6 | 15 |
Max. flow rate | Qmax | m3/h | 3 | 5 | 7 | 12 | 30 |
Insulation limit | Qt | l/h | 120 | 200 | 280 | 480 | 1200 |
Min. flow rate horizontal | Qmin | l/h | 30 | 50 | 70 | 120 | 300 |
Min. flow rate vertical | Qmin | l/h | 60 | 100 | – | – | – |