Menu
Edit Template

Resol DeltaTherm® HC mini Heating controller

4 pre-configured basic systems12 pre-programmed schemes for the temperature controls classes II, III, V, VI, VII and VIII

4 relay outputs (incl. 1 potentil-free extra-low voltage relay)

5 inputs for Pt1000 temperature sensors

5 operating modes, boiler protection, room thermostat and night correction

Holiday mode, chimney sweeper function and screed drying function via microbuttons

Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card

Modulating heating control with 0-10 V boiler control

Resol DeltaSol® CS Solar controller

For the speed control of high-efficiency pumps

1 input for a VFD Grundfos Direct Sensor™

Heat quantity measurement

Commissioning menu

3 basic system layouts to choose from (DeltaSol® CS/4 only)

Function control

Tube collector function, thermal disinfection (DeltaSol® CS/4 only)

Drainback option

Resol DeltaSol® SL Solar controller

4 relay outputs (incl. 1 potential-free extra-low voltage relay)

4 inputs for Pt1000, Pt500 or KTY temperature sensors

Input for 1 analogue Grundfos Direct Sensor™

1 V40 impulse input (also usable as a Pt1000, Pt500 or KTY temperature sensor input)

2 PWM outputs for the speed control of high-efficiency pumps

27 basic system layouts with up to 3 hydraulic variants each to choose from

Automatic function control according to VDI 2169

Resol DeltaSol® CS Plus Solar controller

For the speed control of high-efficiency pumps

1 input for a VFD Grundfos Direct Sensor™

Heat quantity measurement

Commissioning menu

10 basic system layouts to choose from

Function control

Optional thermal disinfection function

Resol DeltaSol® BX Plus System controller

5 relay outputs and 8 inputs for Pt1000, Pt500 or KTY temperature sensors

Up to 2 extension modules via RESOL VBus® (21 sensors and 15 relays in total)

Inputs for digital Grundfos Direct SensorsTM as well as for FRHd humidity sensors

Integrated control of up to 2 high-efficiency pumps via PWM outputs

Data logging, storing, easy transfer of controller adjustments prepared and firmware updates via SD card

Cooling over the heating circuit with condensation detection

Dew point calculation by means of the FRHd humidity sensor to avoid condensation

Resol DeltaSol® BX Solar controller

4 relay outputs and 5 Pt1000 temperature sensor inputs

2 inputs for analogue Grundfos Direct Sensors™

2 PWM outputs for the speed control of high-efficiency pumps

26 basic systems to choose from

Drainback option

Thermal disinfection function, heat dump function

Selection between SI and imperial units

Heat pump demand (optional)

Icma S310 | PT1000 temperature sensor with 1,5 mt. sylicon cable

Working temperature range -50°C + 200°C

Icma S130 | Expansion vessel for solar systems

Max. temperature 140°C