Mixing group with fixed point regulating unit
It is provided with a three way mixing valve regulated by a thermostatic head
with remote sensor art according to which the desired mixed temperature
in the delivery side is set (working temperature range 20°C – 50°C)
The valve has a By-Pass which brings a portion of the return side flow
into the delivery side to obtain the desired temperature of the fluid.
Mixing group with variable point regulation unit
It is provided with a three way mixing valve regulated by a rotating electric servomotor
Connectable to every type of regulating control units
The valve has a By-Pass which brings a portion of the return side flow into the delivery side
to recover heat and to balance the temperature
Calibration and balancing valve with threaded connections
Self-sealing measuring sockets for heating
Cooling and sanitary systems
Equipped with a calibration display and antitampering setting lock
When the value of the valve is set, it can be opened or closed
PN20, max. working temperature 120°C
EPDM gaskets, brass body.
The temperature and pressure relief valve discharges the hot water contained in a storage tank when the temperature is over 100°C or when the pressure is exceeding valve set value
The valve closes when the pressure and/or the temperature decreases within the set tolerances
The valve starts opening at
a temperature between 98°C and 100°C
Female/Female membrane safety valve with 1/4” connection for pressure gauge
Equipped with a pre-mounted pressure gauge
Calibration pressure to be specified
PN 10, max. working temperature 110°C, opening overpressure 10%, closing pressure 20%
The product complies with the Ped
2014/68/UE norm – category IV. CE n. 0425 approval.
Female/Female membrane safety valve
Calibration pressure to be specified
PN 10, max.working temperature 110°C, opening overpressure 10%, closing pressure 20%
The product complies with the Ped
2014/68/UE norm – category IV
CE n. 0425 approval.
Two-way fan coil valve
Flat seat, max. working temperature 110°C
Equipped with ON-OFF normally closed actuator art. 980
Suitable for electrothermic actuators with M30x1,5 connection thread.
Three-way, mixing valve with thermostatic capillary remote sensor
It allows mixing two fluids, resulting in a fluid with intermediate temperature
Setting range 20-50°C
Max. working temperature 95°C, max
Working pressure 10 bars, max
Differential pressure 1 bar
The probe also works when connected;
or immersion use cockpit with sensor art. 212.